Hardline Rescue Kit 5
Rescue kit equipped with a power talk box, suitable for six rescuers
Designed for six technical rescuers
Savox Hardline Rescue Kit 5 enables secured and simultaneous two-way voice communication in confined spaces between rescuers, especially in situations where traditional radios may fail or when hands-free communication is necessary.
Attendants can communicate with confined space rescuers and monitor their safety, while the back-up team can listen to the situation and prepare to help them. The Rescue Kit 5 comes with an additional operator headset and is suitable for six rescuers. The power talk box serves as a portable intercom system, dropped down the hole before entry to assess a victim's condition.
The Savox Hardline Rescue Kit 5 is designed for technical rescue operations such as confined space, structural collapse, high-angle, and trench rescues.
Kit components list
- 1 x CSI-2100 command module
- 1 x Power talk box
- 1 x Cable splitter with protective pouch
- 1 x Cable splitter - double with mic switch
- 2 x Behind head headset single-side, 0,8 m (32") cord
- 4 x Face mask rescue communication set with speaker
- 4 x Speaker harness
- 1 x 0.3 m Operator extension cable with mic mute switch
- 1 x 3 m (10') Operator extension cable with mic mute switch
- 1 x 6 m (20') Operator extension cable with mic mute switch
- 1 x 10 m (32') Cable with connectors
- 1 x 15 m (50') Cable with connectors
- 4 x 30 m (100') Cable with connectors, strain relief & snap hook
- 1 x CSI-2000 carry case with foam
- 1 x Cable bag for 30-91 m (100' – 300') cable
Certifications
Internationally certified
Savox Hardline CSI-2000 systems and approved accessories are intrinsically safe certified in the United States, Canada, EU, UK, and Internationally as listed below.
Note that the products must be powered by approved batteries to meet the certification requirements. For approved battery types, please refer to product-specific control drawings.
Canada
Ex ia IIC T4 Ga
Class I Division 1 Groups A‐D
Temperature Code: T4
Ambient Temperature: ‐20ºC < Ta < 40ºCAccording to standards:
CSA C22.2#60079‐0:2019 Ed.4
CSA C22.2#60079‐11:2014 Ed.2United States
Ex ia IIC T4 Ga
Class I Division 1 Groups A‐D
Temperature Code: T4
Ambient Temperature: ‐20ºC < Ta < 40ºCAccording to standards:
UL 913:2013 Ed.8 + R:06Dec2019
UL 60079-0:2019 Ed.7+R:15Apr2020
UL 60079‐11:2013 Ed.6 +R:28Mar2014European Union
ATEX certification
ATEX II IG Ex ia IIC T4 Ga
-20°C ≤ Ta ≤ +40°CAccording to standards:
EN IEC 60079-0:2018
EN 60079-11:2012International
IECEx certification
IECEx Ex ia IIC T4 Ga
-20°C ≤ Ta ≤ +40°CAccording to standards:
IEC 60079-0:2017
IEC 60079-11:2011UK
UKEX certification
UKEX II IG Ex ia IIC T4 Ga
-20°C ≤ Ta ≤ +40°CAccording to standards:
EN IEC 60079-0:2018
EN 60079-11:2012
The entire system and its accessories are waterproof, with rugged enclosures, external knobs, and signal cables featuring military-grade connectors that resist a wide range of corrosive chemicals, including Skydrol. Combined with the highest level of intrinsic safe approval, this reliability ensures you can trust them with your life.
Contact us
Contact Savox by filling the form below. We will respond to your contact request as soon as possible.